Furrion - Chill Cube Ducted Single-Zone Wall Thermostat & Adapter Kit - Black - 2024047199
Pairs well with




Ready to order
Furrion - Chill Cube Ducted Single-Zone Wall Thermostat & Adapter Kit - Black - 2024047199
Need a Mobile RV Tech Near You?
Connect with certified mobile RV technicians for measurement, installation, or repair — directly through RVService.PRO.
RV Techs
You
Reviewed
Service Too
Customers also bought
- This item: Furrion - Chill Cube Ducted Single-Zone Wall Thermostat & Adapter Kit - Black - 2024047199 $113.95
- Furrion - Chill Cube 18K Ducted Air Distribution Box With Remote - White - FACT18VSDA-PS-AM $185.95
Bought together in 171 orders
Total price $299.90
- This item: Furrion - Chill Cube Ducted Single-Zone Wall Thermostat & Adapter Kit - Black - 2024047199 $113.95
- Furrion - Chill Cube 18K Ducted Air Distribution Box With Remote - White - FACT18VSDA-PS-AM $185.95
- Furrion® - Chill® Cube Variable Speed RV Rooftop Air Conditioner - 18,000 BTU with Heat Pump - White, Ducted - #2025008216 $1,539.99
Bought together in 59 orders
Total price $1,839.89
- This item: Furrion - Chill Cube Ducted Single-Zone Wall Thermostat & Adapter Kit - Black - 2024047199 $113.95
- Furrion - Chill Cube 18K Ducted Air Distribution Box With Remote - White - FACT18VSDA-PS-AM $185.95
- Furrion® - Chill® Cube Variable Speed RV Rooftop Air Conditioner - 18,000 BTU with Heat Pump - Black, Ducted - #2025008215 $1,539.99
Bought together in 37 orders
Total price $1,839.89
---
Item 2024047199 is a thermostat-and-adapter kit for the matching Furrion Chill Cube ducted R32 system, rather than a wall thermostat alone. Lippert lists the thermostat, adapter control box, two mounting screws and manual. Match the complete equipment labels before ordering or wiring.
Earlier Lippert item data used FACW13VSDA-BL-AM / FACC13VSD-AM in its heading, while the manufacturer reference and component chart identify FACW13VSDSA-BL-AM with FACC13VSD-AM. Match item 2024047199 and the actual component labels. The gallery's approximate 4 × 4 inch thermostat face differs from the manual dimensions below; complete-kit dimensions remain unconfirmed.
Features & Specifications
- Kit identity: Lippert2024047199, thermostat plus adapter control box.
- Controls: Manufacturer-listed three fan speeds, Turbo, Gear, Auto, timers, digital LCD/backlight and auto restart.
- Set temperature:60–86°F in the current manufacturer specifications.
- Power:12VDC thermostat input; this does not approve an unspecified RV electrical or furnace interface.
- Heating: Only supported, installed and configured heating equipment; the thermostat does not add a heat pump or furnace.
- Size/weight scope: Manual dimensions and0.27lb weight describe the thermostat, not the complete kit or shipping package. See the source discrepancy below.
Why Choose the Furrion Chill Cube Single-Zone Thermostat?
This kit adds the documented wall-control functions to the identified compatible ducted system. Gear and Turbo change operation of supported equipment; they do not establish a fixed battery-runtime improvement, universal cooling performance or compatibility with every Furrion rooftop unit.
Use the component chart and exact model instructions to match the thermostat, adapter, ADB, rooftop unit and any heating equipment. ClimateSmart and VibrationSmart are manufacturer feature descriptions, not a guarantee against damage or failure. Check actual installation and control requirements before changing equipment.
Compare Furrion RV Thermostats
These links identify different thermostat families. Their own system, refrigerant/generation, controller and wiring requirements must be verified; shared brand or zone count does not approve substitution.
| Model | Zones | Fan Speeds | Special Features | Best For | View Details |
|---|---|---|---|---|---|
| 2024047199 thermostat + adapter kit | Single zone | Three speeds; see model manual | Turbo, Gear, timers; manufacturer-listed auto restart | Exact matching Chill Cube ducted R32 system | Current product |
|
FACW12APZA Enhanced Multi-Zone |
Check exact model | Check exact model | Check exact model | Identification reference; not an approved substitute | View Product → |
|
FACW12ESZA-BL Multi-Zone Standard |
Check exact model | Check exact model | Check exact model | Identification reference; not an approved substitute | View Product → |
|
FACW10SA-BL Standard Single-Zone |
Check exact model | Check exact model | Check exact model | Identification reference; not an approved substitute | View Product → |
Multi-zone and single-zone controls are distinct systems; do not select a replacement using zone count alone.
Technical Specifications
- Lippert item:2024047199.
- Reference model wording: FACW13VSDA-BL-AM in earlier Lippert heading data; FACW13VSDSA-BL-AM in the manufacturer reference/component chart; adapter FACC13VSD-AM. Verify actual labels.
- Thermostat input:12VDC; manual consumption less than0.5W is for the thermostat, not the rooftop AC.
- Temperature set-point range:60–86°F.
- Thermostat dimensions: CCD-0009478 page20 prints4⅜ W ×4⅜ H ×15/16 D inches and111 ×111 ×22.5mm. The two printed depth values do not convert consistently; confirm actual depth/clearance before installation. These figures do not describe the adapter or complete kit.
- Thermostat weight:0.27lb in the manual. Combined kit net weight is not established here; shipping and dimensional weights are not physical item weights.
- Modes and heating: Follow exact equipment/manual configuration. A heat-mode option alone does not establish furnace or heat-pump compatibility.
- Sources: Lippert item 2024047199, CCD-0009478 revision10.21.25, and manufacturer Chill Cube component chart.
What's Included
CCD-0009478 lists one thermostat, one adapter control box, two mounting screws and an instruction manual. The manual notes that product design and packaging may change. Rooftop AC, air distribution box and heating appliances are separate equipment; do not treat a warranty term as a physical kit component or assume extra installation materials are included.
Compatible Models & Alternatives
This kit is an optional control component for the exact matching Chill Cube ducted system. The old links below remain useful for identifying different product families; they do not establish compatibility with this kit or approval to mix R410A, R32, HE or standard-ADB components.
- Furrion Chill Cube HE 15K BTU (R410A) - FACR15HESA-PS — identification reference only; verify its own system and manufacturer requirements.
- Furrion Chill Cube HE 15K BTU (R32) - FACR15HESA2-PS-AM — identification reference only; verify its own system and manufacturer requirements.
- Furrion Chill RV AC Air Distribution Box (R32) - FACT12CA2-PS-AM — identification reference only; verify its own system and manufacturer requirements.
The additional FACW12APZA multi-zone reference is not a drop-in substitute. For model-specific wiring references, see the Chill Cube thermostat wiring guide.
Frequently Asked Questions
How do I install the Furrion Chill Cube thermostat in my RV?
Match item2024047199, the thermostat/adapter labels, rooftop unit, ADB and furnace interface to the applicable manufacturer documents. The kit includes an adapter control box; a12V supply or existing wall opening alone does not establish compatibility. Have a qualified RV technician follow the exact manual, including power-disconnection and wiring requirements. Do not connect by wire color alone.
What is turbo cool mode and when should I use it?
Lippert describes Turbo as a mode intended to cool faster than standard operation. Actual cooldown time depends on the supported rooftop unit, installation and conditions; no fixed cooldown time or battery saving is guaranteed.
Is this thermostat compatible with my Furrion air conditioner?
Check exact model and item numbers rather than brand alone. Lippert identifies2024047199 as an optional kit for the matching Chill Cube ducted system. The component chart and rooftop manual must match the actual equipment. Other Furrion thermostat, R410A, HE or ADB links on this page are identification references, not a confirmed compatibility list.
How does the energy-saving gear mode work?
The manual describes Gear75%, Gear50% and cancellation settings for controlling AC power consumption. Those mode labels do not guarantee the same cooling output, a particular electrical saving, battery compatibility or off-grid runtime in every installation.
What happens to my thermostat settings during a power outage?
Lippert lists auto restart as maintaining settings after a power outage. That feature is not a guarantee against every power fault or loss of clock/timer state. Follow the model-specific manual and check operating and timer settings after power is restored.
Can I program cooling schedules with this thermostat?
CCD-0009478 describes TIMER1 and TIMER2 settings for clock, operating mode, temperature and fan speed. Follow its programming procedure for the identified kit; do not assume an unrestricted weekly scheduling system or guaranteed pre-cooling performance.
Why Buy from Elkhart RV Parts?
Use Lippert item 2024047199 and the actual thermostat, adapter, rooftop and ADB labels to identify this kit. Review the model-specific wiring guide before ordering. Warranty eligibility and remedies depend on the applicable manufacturer terms and purchase evidence; this listing does not promise coverage for an unidentified installation.
Check the complete equipment labels and applicable manual before selecting this thermostat-and-adapter kit. A shared Furrion brand name, wall opening or 12V supply does not establish fit.
| Lippert item | 2024047199 |
|---|---|
| Product type | Single-zone thermostat and adapter kit |
| Voltage | 12VDC thermostat input |
| Color | Black |
| Set temperature range | 60–86°F |
| Fan speeds | Three speeds; mode availability per exact manual |
| Thermostat width (inches) | 4.375 |
| Thermostat height (inches) | 4.375 |
| Thermostat depth source discrepancy | Manual prints15/16in and22.5mm; confirm actual depth |
| Thermostat weight (lb) | 0.27 |
| Complete kit dimensions/net weight | Not established by thermostat-only or shipping figures |
| Thermostat power consumption | Less than0.5W; not rooftop AC draw |
| Included per manufacturer | Thermostat, adapter control box,2mounting screws,manual |
| Manufacturer reference | FACW13VSDSA-BL-AM / FACC13VSD-AM; heading usesVSDA wording |
| Compatibility scope | Exact matching Chill Cube ducted system; verify full equipment and heating configuration |
- What are the fan speed options available on the furrion chill cube thermostat? Lippert lists three fan speeds and Turbo for the matching kit/system. Follow the exact manual for mode availability; no fixed cooldown time is guaranteed.
- Does the furrion chill cube thermostat have an energy-saving mode? The manual describes Gear75%, Gear50% and cancel settings for AC power control. This does not guarantee unchanged cooling performance, a particular saving or battery runtime.
- Can i set a schedule for the air conditioner using this thermostat? The kit manual describes TIMER1 and TIMER2 settings for clock, mode, temperature and fan speed. Use the exact programming procedure; an unrestricted weekly schedule is not established.
- What happens if there is a power outage while using this air conditioner? Lippert lists auto restart as maintaining settings after an outage. Check settings after power restoration; this does not guarantee every clock/timer state through all power faults.
- Is the furrion chill cube thermostat compatible with other furrion air conditioner models? Match the exact thermostat/adapter, rooftop unit and ADB to manufacturer documentation.2024047199 is the documented optional kit for the matching Chill Cube ducted system; other Furrion families are not approved by brand similarity.
Compatible With
Fitment and included components
- Furrion - 18K BTU Variable Speed RV Rooftop Air Conditioner - Chill Cube - Ducted - White - FACR18VSDA-PS-AM: White, cooling only: FACR18VSDA-PS-AM / 2024039645. Optional wall thermostat/adapter kit 2024047199, sold separately. Lippert AM-RC compatibility chart, p.1, Ducted column. Match exact equipment model and controls.
- Furrion - 18K Chill Cube RV AC Bundle - NOT Heat Pump - White Ducted Rooftop Unit & Air Distribution Box - 2024039645: White, cooling only: FACR18VSDA-PS-AM / 2024039645. Optional wall thermostat/adapter kit 2024047199, sold separately. Lippert AM-RC compatibility chart, p.1, Ducted column. Match exact equipment model and controls.
- Furrion - 18K BTU Variable Speed RV Rooftop Air Conditioner - Chill Cube - Ducted - Black - FACR18VSDA-BL-AM: Black, cooling only: FACR18VSDA-BL-AM / 2024039646. Optional wall thermostat/adapter kit 2024047199, sold separately. Lippert AM-RC compatibility chart, p.1, Ducted column. Match exact equipment model and controls.
- Furrion - 18K Chill Cube RV AC Bundle - NOT Heat Pump - Black Ducted Rooftop Unit & Air Distribution Box - 2024039646: Black, cooling only: FACR18VSDA-BL-AM / 2024039646. Optional wall thermostat/adapter kit 2024047199, sold separately. Lippert AM-RC compatibility chart, p.1, Ducted column. Match exact equipment model and controls.
- Furrion® - Chill® Cube Variable Speed RV Rooftop Air Conditioner - 18,000 BTU with Heat Pump - White, Ducted - #2025008216: White, heat pump: FACR18HEDA-PS-AM / 2025008216. Optional wall thermostat/adapter kit 2024047199, sold separately; heat-pump chart specifies optional for furnace operation. Lippert AM-RD compatibility chart, p.1, Ducted column. Match exact equipment model and controls.
- Furrion - 18K Chill Cube Heat Pump Ducted RV AC Bundle - White Rooftop Unit & Air Distribution Box - 2025008216: White, heat pump: FACR18HEDA-PS-AM / 2025008216. Optional wall thermostat/adapter kit 2024047199, sold separately; heat-pump chart specifies optional for furnace operation. Lippert AM-RD compatibility chart, p.1, Ducted column. Match exact equipment model and controls.
- Furrion® - Chill® Cube Variable Speed RV Rooftop Air Conditioner - 18,000 BTU with Heat Pump - Black, Ducted - #2025008215: Black, heat pump: FACR18HEDA-BL-AM / 2025008215. Optional wall thermostat/adapter kit 2024047199, sold separately; heat-pump chart specifies optional for furnace operation. Lippert AM-RD compatibility chart, p.1, Ducted column. Match exact equipment model and controls.
- Furrion - 18K Chill Cube Heat Pump Ducted RV AC Bundle - Black Rooftop Unit & Air Distribution Box - 2025008215: Black, heat pump: FACR18HEDA-BL-AM / 2025008215. Optional wall thermostat/adapter kit 2024047199, sold separately; heat-pump chart specifies optional for furnace operation. Lippert AM-RD compatibility chart, p.1, Ducted column. Match exact equipment model and controls.
Ready to order
Furrion - Chill Cube Ducted Single-Zone Wall Thermostat & Adapter Kit - Black - 2024047199
Need a Mobile RV Tech Near You?
Connect with certified mobile RV technicians for measurement, installation, or repair — directly through RVService.PRO.
RV Techs
You
Reviewed
Service Too
Loading customer reviews…
Questions & Answers
Does the Furrion Chill Cube single-zone thermostat kit include the adapter control box?
Yes. Furrion lists the FACC13VSD adapter control box as included with the thermostat kit.
Factory-Fresh OEM Parts — the same brands installed in new RVs straight from Elkhart. Genuine, name-brand components made to order — never generic, never outdated. Sourced directly from the original RV manufacturers for perfect fit and factory-level quality.








