{"product_id":"dometic-penguin-ii-air-conditioner-replacement-capacitor-kit-60-15-mfd","title":"Dometic AC Capacitor 60\/15 MFD - Penguin II Air Conditioner - Part# 3314471.019","description":"\u003cdiv class=\"erp-pdp\"\u003e\n\n\u003cp\u003eThe Dometic 3314471.019 is a dual-run capacitor designed specifically for Dometic Penguin II rooftop air conditioners. This 60\/15 MFD capacitor provides the electrical boost needed to start and run both the compressor and fan motor in your RV's AC unit. If your air conditioner won't start, runs intermittently, or the compressor hums without starting, a failed capacitor is often the culprit. This genuine OEM replacement ensures reliable cooling performance and proper electrical operation.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#dc2626;margin:32px 0 16px;padding-bottom:10px;border-bottom:3px solid #dc2626;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"line-height:1.8;margin-bottom:24px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Run Design:\u003c\/strong\u003e 60 MFD for compressor start\/run, 15 MFD for fan motor operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePenguin II Specific:\u003c\/strong\u003e Engineered for Dometic Penguin II rooftop air conditioner models\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Quality:\u003c\/strong\u003e Genuine Dometic replacement part ensures proper fit and electrical specifications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Rated:\u003c\/strong\u003e Built to withstand the heat generated in RV rooftop AC units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Replacement:\u003c\/strong\u003e Exact fit for original equipment - no modifications required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Component:\u003c\/strong\u003e Essential for proper compressor and fan motor operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#dc2626;margin:32px 0 16px;padding-bottom:10px;border-bottom:3px solid #dc2626;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table table-bordered table-sm\" style=\"margin-bottom:24px;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:600;background:#f8f9fa;width:35%;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3314471.019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:600;background:#f8f9fa;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e60\/15 MFD (Microfarads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:600;background:#f8f9fa;\"\u003eType\u003c\/td\u003e\n\u003ctd\u003eDual-Run Capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:600;background:#f8f9fa;\"\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCompressor and Fan Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight:600;background:#f8f9fa;\"\u003eCompatible System\u003c\/td\u003e\n\u003ctd\u003eDometic Penguin II Air Conditioners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#dc2626;margin:32px 0 16px;padding-bottom:10px;border-bottom:3px solid #dc2626;\"\u003eCompatibility\u003c\/h2\u003e\n\u003ctable class=\"table table-bordered table-sm\" style=\"margin-bottom:24px;\"\u003e\n\u003ctr style=\"background:#f8f9fa;font-weight:600;\"\u003e\n\u003ctd\u003eModel Series\u003c\/td\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePenguin II\u003c\/td\u003e\n\u003ctd\u003eRooftop Air Conditioner Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#dc2626;margin:32px 0 16px;padding-bottom:10px;border-bottom:3px solid #dc2626;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003cdiv style=\"margin-bottom:16px;\"\u003e\n\u003cstrong style=\"color:#333;font-size:16px;\"\u003eQ: How do I know if my capacitor has failed?\u003c\/strong\u003e\n\u003cp style=\"margin:8px 0 0 0;line-height:1.6;\"\u003eA: Common signs include the AC compressor humming but not starting, the unit cycling on and off rapidly, reduced cooling performance, or the fan running but compressor not engaging. A bulging or leaking capacitor is a visual indicator of failure. Always disconnect power before inspecting electrical components.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom:16px;\"\u003e\n\u003cstrong style=\"color:#333;font-size:16px;\"\u003eQ: What do the 60 and 15 MFD ratings mean?\u003c\/strong\u003e\n\u003cp style=\"margin:8px 0 0 0;line-height:1.6;\"\u003eA: This is a dual-run capacitor with two separate capacitance values. The 60 MFD section provides the electrical boost for the compressor to start and run, while the 15 MFD section powers the fan motor. Both ratings must match your original capacitor exactly for proper operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom:16px;\"\u003e\n\u003cstrong style=\"color:#333;font-size:16px;\"\u003eQ: Can I replace this capacitor myself?\u003c\/strong\u003e\n\u003cp style=\"margin:8px 0 0 0;line-height:1.6;\"\u003eA: If you're comfortable working with electrical components and follow proper safety procedures, capacitor replacement is straightforward. Always disconnect shore power and turn off the breaker before starting. Take a photo of wire connections before removal, and discharge the old capacitor safely. If unsure, consult a qualified RV technician.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom:16px;\"\u003e\n\u003cstrong style=\"color:#333;font-size:16px;\"\u003eQ: Will this work with other Dometic AC models besides Penguin II?\u003c\/strong\u003e\n\u003cp style=\"margin:8px 0 0 0;line-height:1.6;\"\u003eA: This capacitor is specifically designed for Penguin II models. Other Dometic air conditioner series may require different capacitance ratings. Always verify your model number and existing capacitor specifications before ordering to ensure proper compatibility and safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#dc2626;margin:32px 0 16px;padding-bottom:10px;border-bottom:3px solid #dc2626;\"\u003eWhy Choose Elkhart RV Parts?\u003c\/h2\u003e\n\u003cp style=\"line-height:1.8;margin-bottom:16px;\"\u003eAt ElkhartRVParts.com, we specialize in hard-to-find Dometic replacement parts that keep your RV systems running smoothly. Located in Elkhart, Indiana — the RV Capital of the World — we understand the importance of getting the right part quickly. This genuine OEM capacitor ensures your Penguin II air conditioner operates safely and efficiently, providing reliable cooling when you need it most.\u003c\/p\u003e\n\n\u003cp style=\"line-height:1.8;margin-bottom:16px;\"\u003eWe stock authentic Dometic parts and ship fast from our Indiana warehouse. Our team knows RV air conditioning systems inside and out, so if you have questions about compatibility or installation, we're here to help. When your AC goes down in the middle of summer, you need the right part fast — and that's exactly what we deliver.\u003c\/p\u003e\n\n\u003cdiv style=\"background:#f3f4f6;border-left:4px solid #dc2626;padding:16px;margin-top:24px;\"\u003e\n\u003cstrong style=\"color:#dc2626;\"\u003e✓ Genuine Dometic OEM Part\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong style=\"color:#dc2626;\"\u003e✓ Fast Shipping from Elkhart, Indiana\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong style=\"color:#dc2626;\"\u003e✓ Expert RV Parts Support\u003c\/strong\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Dometic","offers":[{"title":"Default Title","offer_id":48317347168408,"sku":"3314471.019","price":39.99,"currency_code":"USD","in_stock":true}],"url":"https:\/\/elkhartrvparts.com\/products\/dometic-penguin-ii-air-conditioner-replacement-capacitor-kit-60-15-mfd","provider":"Elkhart RV Parts","version":"1.0","type":"link"}